# user space component for controlling a misubishi inverter over the serial port using rs485 standard
# specifcally the A500 F500 E500 A500 D700 E700 F700 series - others may work or need adjustment
# tested on A500 E500 and E700
# I referenced manual 'communication option reference manual' and A500 technical manual for 500 series.
# 'Fr-A700 F700 E700 D700 technical manual' for the 700 series
#
# The inverter must be set manually for communication ( you may have to set PR 77 to 1 to unlock PR modifcation )
# must power cycle the inverter for some of these to register eg 79
# PR 79 - 1 or 0
# PR 117 station number - 1               (can be optionally set 0 - 31) if component is also set
# PR 118 communication speed 96           (can be optionally set 48,96,192) if component is also set
# PR 119 stop bit/data length - 0         8 bits, two stop (don't change)
# PR 120 parity - 0                       no parity (don't change)
# PR 121 COM tries - 10                   if 10 (maximuim) COM errors then inverter faults (can change)
# PR 122 COM check time interval 9999     (never check) if communication is lost inverter will not know (can change)
# PR 123 wait time - 9999 -               no wait time is added to the serial data frame (don't change)
# PR 124 CR selection - 0                 don't change

import time,hal
import serial
import traceback
class mitsubishi_serial:

    def __init__(self,vfd_names=[['mitsub_vfd','00']],baudrate=9600,port='/dev/ttyUSB0'):
        try:
            self.ser = serial.Serial(
            port,
            baudrate,
            parity=serial.PARITY_NONE,
            stopbits=serial.STOPBITS_TWO,
            bytesize=serial.EIGHTBITS
            )
            self.ser.open()
            self.ser.isOpen()
        except:
            print("ERROR : mitsub_vfd - No serial interface found at %s"% port)
            raise SystemExit
        print("Mitsubishi VFD serial computer link has loaded")
        print("Port: %s,\nbaudrate: %d\n8 data bits, no parity, 2 stop bits\n"%(port,baudrate))

        self.h=[]
        self.comp_names = vfd_names
        for index,name in enumerate(self.comp_names):
            #print index,' NAME:',name[0],' SLAVE:',name[1]
            c = hal.component(name[0])
            c.newpin("fwd", hal.HAL_BIT, hal.HAL_IN)
            c.newpin("run", hal.HAL_BIT, hal.HAL_IN)
            c.newpin("up-to-speed", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("alarm", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("debug", hal.HAL_BIT, hal.HAL_IN)
            c.newpin("monitor", hal.HAL_BIT, hal.HAL_IN)
            c.newpin("motor-cmd", hal.HAL_FLOAT, hal.HAL_IN)
            c.newpin("motor-fb", hal.HAL_FLOAT, hal.HAL_OUT)
            c.newpin("motor-amps", hal.HAL_FLOAT, hal.HAL_OUT)
            c.newpin("motor-power", hal.HAL_FLOAT, hal.HAL_OUT)
            c.newpin("scale-cmd", hal.HAL_FLOAT, hal.HAL_IN)
            c.newpin("scale-fb", hal.HAL_FLOAT, hal.HAL_IN)
            c.newpin("scale-amps", hal.HAL_FLOAT, hal.HAL_IN)
            c.newpin("scale-power", hal.HAL_FLOAT, hal.HAL_IN)
            c.newpin("estop", hal.HAL_BIT, hal.HAL_IN)
            c.newpin("stat-bit-0", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-1", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-2", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-3", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-4", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-5", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-6", hal.HAL_BIT, hal.HAL_OUT)
            c.newpin("stat-bit-7", hal.HAL_BIT, hal.HAL_OUT)
            # set reasonable defaults
            c['scale-cmd'] = 1
            c['scale-fb'] = 1
            c['scale-amps'] = 1
            c['scale-power'] = 1
            c['fwd'] = 1
            # flags for each device
            self['last_run%d'%index] = c['run']
            self['last_fwd%d'%index] = c['fwd']
            self['last_cmd%d'%index] = c['motor-cmd']
            self['last_monitor%d'%index] = c['monitor']
            self['last_estop%d'%index] = c['estop']
            #add device to component reference variable
            self.h.append(c)
            print("Mitsubishi %s VFD: slave# %s added\n"%(name[0],name[1]))
        # only issue ready when all the components are ready
        for i in self.h:
            i.ready()

    def loop(self):
        cmd = data = out = temp=''
        while 1:
            try:
              for index,ids in enumerate(self.comp_names):
                self.slave_num = ids[1]
                # MONITOR for up-to-speed, alarms and running frequency
                # 7A is the address for 8 status bits ( b0 - b8 )
                # These bits are configurable from the panel. We assume bit 3 is up to speed
                # and bit 7 is alarm
                # the returned data is 2 characters of hex
                # we convert that to binary and the mask for the bits we want
                if self.h[index]['monitor']:
                    while self.ser.inWaiting() > 0:
                        raw = self.ser.read(1)
                    word = self.prepare_data("7A",None)
                    out = temp = ''
                    self.ser.write(word)
                    time.sleep(.05)
                    string,chr_list,chr_hex = self.poll_output()
                    #print 'DEBUG: ',chr_list,chr_hex
                    if chr_list != '':
                        #print string
                        try:
                            binary = "{0:#010b}".format(int(string[3:5],16))
                        except:
                            binary = '0b000000'
                        self.h[index]['stat-bit-0'] = int(binary,2) & 1
                        self.h[index]['stat-bit-1'] = int(binary,2) & 2
                        self.h[index]['stat-bit-2'] = int(binary,2) & 4
                        self.h[index]['stat-bit-3'] = self.h[index]['up-to-speed'] = int(binary,2) & 8
                        self.h[index]['stat-bit-4'] = int(binary,2) & 16
                        self.h[index]['stat-bit-5'] = int(binary,2) & 32
                        self.h[index]['stat-bit-6'] = int(binary,2) & 64
                        self.h[index]['stat-bit-7'] = self.h[index]['alarm'] = int(binary,2) & 128
                        if self.h[index]['debug'] and 1==2:
                            print('monitor operation:',binary,temp,temp[3:5],len(temp))

                    # 6F is the address for running motor frequency status
                    # it returns 4 characters of hex
                    # we convert to decimal and multiply by .01 for hertz and by user scale-fb
                    # for arbrtrary units. This does require scale to be set to something besides 0!
                    # we assume the inverter is set to show running hertz (it's configurable in the VFD)
                    word = self.prepare_data("6F",None)
                    out = temp = ''
                    self.ser.write(word)
                    time.sleep(.05)
                    string,chr_list,chr_hex = self.poll_output()
                    if self.h[index]['debug']:
                        print('DEBUG: ',chr_list,chr_hex)
                    if chr_list != '':
                        decimal = int(string[3:7],16)
                        self.h[index]["motor-fb"] = decimal *.01 * self.h[index]["scale-fb"]
                        if self.h[index]['debug'] and 1==2:
                            print('monitor frequency:',decimal,string,string[3:7], len(string))

                # amps
                    word = self.prepare_data("70",None)
                    out = temp = ''
                    self.ser.write(word)
                    time.sleep(.05)
                    time.sleep(.05)
                    string,chr_list,chr_hex = self.poll_output()
                    if self.h[index]['debug']:
                        print('DEBUG: ',chr_list,chr_hex)
                    if chr_list != '':
                        decimal = int(string[3:7],16)
                        self.h[index]["motor-amps"] = decimal *.01 * self.h[index]["scale-amps"]
                        if self.h[index]['debug'] and 1==2:
                            print('monitor amps:',decimal,string,string[3:7], len(string))


                # STOP ON ESTOP
                # if ESTOP is false it stops the output
                # when ESTOP is reset the run command must be re-issued (cycled false to true) to start motor 
                if not self['last_estop%d'%index] == self.h[index]['estop']:
                    if not self.h[index]["estop"]:
                        cmd = "FA";data ="00"
                        word = self.prepare_data(cmd,data)
                        self.ser.write(word)
                        time.sleep(.05)
                        self['last_estop%d'%index] = self.h[index]['estop']
                        print("**** Mitsubishi VFD: %s stopped due to Estop Signal"% ids[0])
                        continue
                    print("**** Mitsubishi VFD: Estop cleared - Must re-issue run command to start %s." % ids[0])
                    self['last_estop%d'%index] = self.h[index]['estop']

                # SET RUN AND DIRECTION
                # address FA sets the start and direction
                # it expects a 2 character hex representing a 8 bit (b0 - b7) binary number
                # bit 1 sets forward, 4 sets reverse, 0 stop
                # depending on the inverter and options other bits are possible,
                # but these three are consistant
                if not self['last_run%d'%index] == self.h[index]['run'] or not self['last_fwd%d'%index] == self.h[index]['fwd']:
                    if self.h[index]['run']:
                        if self.h[index]['fwd']:
                            cmd = "FA";data ="02"
                        else:
                            cmd = "FA";data ="04"
                    else:
                        cmd = "FA";data ="00"
                    word = self.prepare_data(cmd,data)
                    self.ser.write(word)
                    time.sleep(.05)
                    self['last_run%d'%index] = self.h[index]['run']
                    self['last_fwd%d'%index] = self.h[index]['fwd']
                    if self.h[index]['debug']:
                        string,chr_list,chr_hex = self.poll_output()
                        print('DEBUG: ',chr_list,chr_hex)

                # SET cmd
                # address ED is for setting the running frequency
                # it expects 4 characters of hex representing frequency in .01 hertz units
                # we internally scale it by 100 to make it 1 hertz units and by user scale
                # for arbrtrary units. This does require scale to be set to something besides 0!
                if not self['last_cmd%d'%index] == self.h[index]['motor-cmd']:
                    freq = int(abs(self.h[index]['motor-cmd']*100*self.h[index]['scale-cmd']))
                    if freq > 40000: freq = 40000
                    if freq < 0: freq = 0
                    self['last_cmd%d'%index] = self.h[index]['motor-cmd']
                    # send frequency command
                    cmd="ED";data="%0.4X"%freq
                    word = self.prepare_data(cmd,data)
                    self.ser.write(word)
                    time.sleep(.05)
                    if self.h[index]['debug']:
                        string,chr_list,chr_hex = self.poll_output()
                        print('DEBUG: ',chr_list,chr_hex)

            except KeyboardInterrupt:
                    self.kill_output()
                    raise
            except:
                    print("error",ids)
                    print(sys.exc_info()[0])

    def kill_output(self):
        cmd = "FA";data ="00"
        for index,ids in enumerate(self.comp_names):
            self.slave_num = ids[1]
            word = self.prepare_data(cmd,data)
            self.ser.write(word)
            time.sleep(.05)
            print('Mitsub VFD: Kill-> ', ids[0])

    def prepare_data(self,command ='E1',data= '07AD'):
        combined = self.slave_num+command  +'1'
        if not data == None:
            combined += data
        s=0
        for i in range(0,len(combined)):
            letter = combined[i]
            s=s+ord(letter.upper())
        converted_data = chr(0x5) + combined + hex(s)[-2:-1].upper() + hex(s)[-1:].upper()
        return converted_data

    def poll_output(self):
        string = chr_list_out = hex_out = ''
        while self.ser.inWaiting() > 0:
            raw = self.ser.read(1)
            chr_list_out += raw+','
            string += raw
            hex_out += hex(ord(raw))
            hex_out +=' '
        if hex_out != '':
            answ=''
            if chr_list_out[0] == chr(0x6):
                answ = 'ackg'
            if chr_list_out[0] == chr(0x15):
                answ = 'error'
            if chr_list_out[0] == chr(0x2):
                answ = 'checksome error'
            #print 'slave:',chr_list_out[2]+chr_list_out[4],answ
            return string,chr_list_out,hex_out
        return '','',''

    def __getitem__(self, item):
        return getattr(self, item)
    def __setitem__(self, item, value):
        return setattr(self, item, value)

if __name__ == "__main__":
    import getopt,sys
    letters = 'p:b:h' # the : means an argument needs to be passed after the letter
    keywords = ['port=', 'baud=' ] # the = means that a value is expected after 
    # the keyword
    opts, extraparam = getopt.getopt(sys.argv[1:],letters,keywords) 
    # starts at the second element of argv since the first one is the script name
    # extraparms are extra arguments passed after all option/keywords are assigned
    # opts is a list containing the pair "option"/"value"
    port='/dev/ttyS0'
    device_ids=[]
    baud=9600

    for o,p in opts:
      if o in ['-p','--port']:
         port = p
      elif o in ['-b','--baud']:
         baud = p
      elif o in ['-h','--help']:
        print('Mitsubishi VFD computer-link interface')
        print(' User space component for controlling a misubishi inverter over the serial port using the rs485 standard')
        print(' specifcally the A500 F500 E500 A500 D700 E700 F700 series - others may work or need small adjustments')
        print(''' I referenced manual 'communication option reference manual' and A500 technical manual for 500 series.''')
        print(''' 'Fr-A700 F700 E700 D700 technical manual' for the 700 series''')
        print() 
        print(' The inverter must be set manually for communication ( you may have to set PR 77 to 1 to unlock PR modifcation )')
        print(' You must power cycle the inverter for some of these to register eg 79')
        print(' PR 79 - 1 or 0                          sets the inverter to respond to the PU/computer-link')
        print(' PR 117 station number (slave) - 1       can be optionally set 0 - 31 if component is also set')
        print(' PR 118 communication speed 96           baud rate, can be optionally set 48,96,192 if component is also set')
        print(''' PR 119 stop bit/data length - 1         8 bits, two stop (don't change)''')
        print(''' PR 120 parity - 0                       no parity (don't change)''')
        print(' PR 121 COM tries - 10                   if 10 (maximuim) COM errors then inverter faults (can change)')
        print(' PR 122 COM check time interval 9999     (never check) if communication is lost inverter will not know (can change)')
        print(''' PR 123 wait time - 9999 -               no wait time is added to the serial data frame (don't change)''')
        print(''' PR 124 CR selection - 0                 don't change''')
        print('''
This driver assumes certain other VFD settings:
-That the  motor frequency status is set to show herts.
-That the status bit 3 is up to speed
-That the status bit 7 is alarm
''')
        print()
        print('''some models (eg E500) cannot monitor status -set the monitor pin to false
in this case pins such as up-to-speed, amps, alarm and status bits are not useful.
''')
        print('''HAL command used to load: ''')
        print('''loadusr mitsub_vfd --baud 4800 --port /dev/ttyUSB0 NAME=SLAVE_NUMBER 
        -NAME is user selectable (usually a description of controlled device)
        -SLAVE_NUMBER is the slave number that was set on the VFD
        -NAME=SLAVE_NUMBER can be repeated for multiple VFD's connected together
        --baud is optional as it defaults to 9600
        all networked vfds must be set to the same baudrate
        --port is optional as it defaults to ttyS0''')
        print()
        print(''' Sample linuxcnc code
loadusr -Wn coolant mitsub_vfd spindle=02 coolant=01
# **************** Spindle VFD setup slave 2 *********************
net spindle-vel-cmd               spindle.motor-cmd
net spindle-cw                    spindle.fwd              
net spindle-on                    spindle.run              
net spindle-at-speed              spindle.up-to-speed
net estop-out                     spindle.estop
#       cmd scaled to RPM
setp spindle.scale-cmd .135
#       feedback is in rpm
setp spindle.scale-fb 7.411
setp spindle.monitor 1

net spindle-speed-indicator spindle.motor-fb        gladevcp.spindle-speed
# *************** Coolant vfd setup slave 3 ***********************
net coolant-flood                         coolant.run
net coolant-is-on              coolant.up-to-speed   gladevcp.coolant-on-led
#       cmd and feedback scaled to hertz
setp coolant.scale-cmd 1
setp coolant.scale-fb 1
#       command full speed
setp coolant.motor-cmd 60
#       allows us to see status
setp coolant.monitor 1
net estop-out                     coolant.estop
''')
        sys.exit(0)
    if extraparam:
        for dids in extraparam:
            device_ids.append(dids.split('='))
    else:
        device_ids=[['mitsub_vfd','00']]
    print(port,baud)
    # Info gathered now use them
    try:
        app = mitsubishi_serial(vfd_names=device_ids,baudrate=int(baud),port=port)
        app.loop()
    except KeyboardInterrupt:
        sys.exit(0)
    else:
            exc_type, exc_value, exc_traceback = sys.exc_info()
            formatted_lines = traceback.format_exc().splitlines()
            print()
            print("**** Mitsub_vfd debugging:",formatted_lines[0])
            traceback.print_tb(exc_traceback, limit=1, file=sys.stdout)
            print(formatted_lines[-1])